z-logo
open-access-imgOpen Access
Determination of background indoor air pollutants and thermal comfort in faculty of earth science building
Author(s) -
Norrimi Rosaida Awang,
N. A. N. M. Radzi,
T. S. Yong,
M. Amir Abas,
Nazatul Syadia Zainordin,
Nor Azam Ramli,
Nik Lukman Nik Ibrahim
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/842/1/012003
Subject(s) - indoor air quality , ashrae 90.1 , particulates , environmental science , thermal comfort , relative humidity , air conditioning , pollutant , humidity , environmental chemistry , environmental engineering , meteorology , chemistry , engineering , mechanical engineering , physics , organic chemistry
The focus of this study was to determine the most significant factors that influencing indoor air quality (IAQ) and thermal comfort of a mechanically ventilated lecturer office room in FSB new building. This study measured the concentrations of ozone (O 3 ), nitrogen dioxide (NO 2 ), total volatile organic compound (TVOC), carbon dioxide (CO 2 ), carbon monoxide (CO), particulate matter (PM), temperature and relative humidity using seven set up conditions. The set-up condition for study room is based on temperatures that have been selected between 22°C to 26°C and window of the room being either close or open. The IAQ were analyzed by descriptive analysis to indicate the parameters variations. Furthermore, thermal comfort for the room of FSB new building has been determine by the CBE thermal comfort tool based on ASHRAE 55 standards. Result suggested that the IAQ of the studied room in FSB new building showed maximum reading during the window was opened condition. The setup of selected temperature air conditioner was minimizing the concentrations of IAQ because IAQ were increase during high temperature. Among of the selected IAQ parameters, particulate matter was the most significant indoor air pollutants in the studied room with the highest average concentration was 20.944 μg/m 3 . The increment of particulate matter concentrations was due to the suspended dust in the room and additional movements of the occupants inside the room exaggerate the condition. Besides, results of this study suggested that a good IAQ inside an air conditioning room was achieved when the temperature is set at 26°C.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here