Open Access
Modification Works of Impressed Current Cathodic Protection System for Steel Sheet Piles Bulkhead Wharf
Author(s) -
Yan Li,
Qiang Liu,
Yongkun Qin,
Xichang Zhu
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/668/1/012048
Subject(s) - cathodic protection , wharf , corrosion , bulkhead (partition) , sheet pile , metallurgy , seawater , brass , materials science , galvanic anode , perforation , forensic engineering , engineering , marine engineering , composite material , geology , geotechnical engineering , anode , chemistry , copper , pile , oceanography , electrode , punching
The steel sheet piles have been protected effectively by the cathodic protection system against seawater corrosion for 40 years. There is no phenomenon of corrosion perforation and corrosion damage. However, many instruments and parts of the cathodic protection system do not work properly now, whilst many new cathodic protection materials are produced and more effective. In order to prevent the steel sheet piles from seawater corrosion, the ICCP system should been modified perfectly.