Study on transfer characteristics of pressure fluctuation in a prototype pump-turbine
Author(s) -
J. W. Li,
X. R. Liu
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/627/1/012001
Subject(s) - amplitude , turbine , hydraulic turbines , power station , mechanics , power (physics) , transfer (computing) , research object , control theory (sociology) , environmental science , phase (matter) , vibration , transfer function , acoustics , meteorology , computer science , physics , engineering , thermodynamics , optics , electrical engineering , geography , artificial intelligence , control (management) , quantum mechanics , regional science , parallel computing
Considering unit 3 in Zhanghewan pumped storage power station as the research object, transfer characteristics of pressure fluctuation at the vaneless area were studied from the dominant frequencies, the fractional amplitude and the fractional phase at four different measuring points. It was revealed that the variation trends of pressure fractional amplitude (50Hz and 100Hz) versus output agreed well at the four points, and the phase difference between the four points varied very small with increasing of output under different water heads. This research could provide instructive inspiration for solving the vibration problems in pumped storage power station, and provide useful thinking for optimizing hydraulic design of the pump-turbine.