Design Water Level Calculation And Analysis Of Chittagong Power Plant Project In Bangladesh
Author(s) -
Ning Guan,
Hanbao Chen,
Yong Xu,
Luan Ying-ni,
Zhijia Tan
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/621/1/012152
Subject(s) - water level , environmental science , water resource management , geography , cartography
The design water level calculation methods in the Chinese and foreign codes are different. The design high and low water levels and extreme high and low water levels in the Chinese norms are calculated using historical cumulative frequencies with tide level data of not less than 1 year and 20 years, respectively. In foreign norms, the average high and low tide levels of spring tides are mostly used as the design high and low water levels, and for the sea areas lacking long-term measured data, the water level combination method is mostly used to determine the extreme water levels. This paper compares the results of different methods used to calculate the design water level using the Chittagong Power Plant in Bangladesh as an example. The calculations show that it is safer to use the tidal eigenvalue method to determine the design high and low water levels, and that the Water Level Combination Method is more suitable for extreme water level determination than Bangladesh National Building Code.