z-logo
open-access-imgOpen Access
Structural selection and design analysis of a super high-rise office building
Author(s) -
Xiaomeng Zhang,
Wenting Liu,
Yongxin Li,
Shu Yang,
Xiang Liu
Publication year - 2020
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/510/5/052004
Subject(s) - structural engineering , structural system , seismic analysis , limit analysis , engineering , geology , finite element method
A super high-rise building, with a height of 238 meters, 4 floors underground and 50 floors above the ground, exceeds the Class B height limit of the specification, and belongs to an ultra-high over-limit structure. Through the selection of different structural systems, its structural system is determined as the frame core tube structure. This structure uses YJK, SATWE, PKPM-SAUSAGE for structural analysis, uses performance-based methods for seismic design, and the weak parts of the structure are strengthened accordingly. Structural analysis mainly includes elasticity analysis of small earthquakes, elastic time history analysis of small earthquakes, elastic and inflexion analysis of moderate earthquakes, inflexibility analysis of large earthquakes and elastoplastic time history analysis of large earthquakes.