z-logo
open-access-imgOpen Access
Simulation and experimental analysis of shell and tube heat exchanger for the drying system
Author(s) -
Songchai Pankaew,
Samerkhwan Tantikul,
Thanasit Wongsiriamnuay,
Tipapon Khamdaeng,
Nakorn Tippayawong,
Numpon Panyoyai
Publication year - 2020
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/463/1/012132
Subject(s) - heat exchanger , micro heat exchanger , shell and tube heat exchanger , concentric tube heat exchanger , ntu method , heat transfer , airflow , plate heat exchanger , thermodynamics , materials science , heat transfer coefficient , plate fin heat exchanger , dynamic scraped surface heat exchanger , mechanics , chemistry , critical heat flux , physics
In this research, heat transfer simulation is a part of the application of heat transfer from the biochar production process for the drying system. This research aimed to investigate the three-dimensional transient conditions of the simulation used to predict heat transfer of heat exchangers comparing with the experimental study. The working fluid used inside the tube was hot water with a mass flow rate of 10 LPM. The results obtained from the simulation and the experiment analysis were heat transfer from hot water to cold air through the heat exchangers. The temperatures of hot water inlet the heat exchanger were set as 50, 60, 70, and 80 °C, respectively. Air flowed through the heat exchangers was set as 1 m/s, 2 m/s, 3 m/s, 4 m/s, and 5 m/s, respectively. The coil pipe has the outsider diameter at 1.9 cm and four panels. It was set up on a box case with 100 cm of width and height and 45 cm of length. The results showed that when the water temperature increased from 50 °C to 80 °C and airflow speed through the heat exchangers of 3 m/s, the temperature difference of air through the heat exchangers increased from 3.2 °C, 4.7 °C, 5.20 °C and 6.2 °C respectively. On the other hand, when the airflow speed through the heat exchangers increased from 1 m/s to 2 m/s, 3 m/s, 4 m/s and 5 m/s respectively, the temperature difference of air through the heat exchangers decreased from 11.81 °C to 7.33 °C, 6.20 °C, 5.20 °C, and 5.05 °C respectively. The simulated heat transfer coefficient inside the region of heat exchangers was an agreement with the experimental data. The results indicated that the simulation could be attained in the system compared with the actual experimental analysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here