The application of PAC and PAM in dynamic treatment of beryllium copper wastewater
Author(s) -
Yang Shen
Publication year - 2020
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/450/1/012076
Subject(s) - clarifier , wastewater , beryllium , copper , chemistry , filtration (mathematics) , volumetric flow rate , nuclear chemistry , chromatography , waste management , organic chemistry , engineering , statistics , physics , mathematics , quantum mechanics
The dynamic removal of beryllium and copper element was achieved by slanting plate clarifier after the wastewater of beryllium copper production line was settled by PAC and PAM. When the pH of wastewater was 9.0, PAC with a mass concentration of 50 mg/L at a flow rate of 200-250 L/h and PAM with a mass concentration of 2 mg/L at a flow rate of 150-200 L/h were injected in the wastewater sequence, respectively. The treated wastewater flowed through the slanting plate clarifier at a flow rate of 30 m3/h and then filtered continuously through the filtration device. The results show that Be 2+ and Cu 2+ concentrations are lower than 5 μg/L and 2 mg/L, respectively, which complies with the Standards of GB 8978—1996. Therefore, the Be2+ and Cu2+ elements in the wastewater can be removed at the same time.