z-logo
open-access-imgOpen Access
Assessment of the efficiency of the wastewater treatment plant: a case of Gacuriro Vision City
Author(s) -
M J Nikuze,
John Bosco Niyomukiza,
A Nshimiyimana,
J P Kwizera
Publication year - 2020
Publication title -
iop conference series earth and environmental science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.179
H-Index - 26
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/448/1/012046
Subject(s) - grease , chemical oxygen demand , wastewater , effluent , biochemical oxygen demand , total suspended solids , sewage treatment , suspended solids , phosphorus , chemistry , environmental science , pulp and paper industry , environmental engineering , zoology , environmental chemistry , biology , biochemistry , organic chemistry , engineering
Wastewater is the liquid waste generated after being used for different purposes. It has a great impact on the environment when discharged untreated or partially treated. The poor management of wastewater at Gacuriro wastewater plant leads to the discharge of subsequently untreated and partially treated wastes. Therefore, the research focused on the assessment of the efficiency of Gacuriro wastewater treatment plant. Samples of wastewater were collected at the inlet and outlet of the treatment plant for laboratory analysis. Parameters tested include pH, Temperature, Total Suspended Solids (TSS), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Coliform (TC), Oil and Grease, and Total Phosphorus (TP). Inlet and outlet results are 112.5-364.5 mg/l, 60-190.2 mg/l for BOD; 447-820 mg/l, 46.6-300 mg/l for COD, 19-24 mg/l, 12-18 mg/l for TSS; 6.8-9.05 mg/l, 6.4-5.75 mg/l for TP, 2419.6-50000 counts/100 ml, 1730-30000 counts/100 ml for TC, and 1.012-1.079 mg/l, 0.75-0.923 mg/l for Oil and Grease. Their percentage reduction of efficiency were in the range of TSS (62.50-75%), COD (63.05-78.74%), BOD5 (69.97-83.70%), Oil and Grease (48.67-62.19%), TP (49.26-60.82%), TC (57.14-64.00%) while average inflow and outflow discharge are 2.5 l/s and 1.5 l/s, respectively. The effluent from the treatment plant needs improvement in disinfection systems to remove bacteria out of discharged effluent.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom