Subject(s) - dynamic balance , vibration , rotor (electric) , gas turbines , turbine , balance (ability) , engineering , physics , mechanical engineering , acoustics , physical medicine and rehabilitation , medicine
The on-site vibration test and diagnostic analysis of the condensate pump motor vibration of a 390 MW gas turbine unit in a power plant were carried out. It is considered that the serious imbalance of the rotor of the condensate pump motor is the main cause of the vibration abnormality of the motor. The vibration anomaly is eliminated by the on-site dynamic balance test.