
Does exposure to inflammatory particles modify the pattern of anion in exhaled breath condensate?
Author(s) -
JeanJacques Sauvain,
Jean-Louis Edmé,
Pascal Wild,
Guillaume Suárez,
Olivia Maria de Paula Alvez Bezerra,
André Talvani,
Eduardo Algranti,
Ana Paula Scalio Carneiro,
Nathalie ChérotKornobis,
Annie Sobaszek,
Sébastien Hulo
Publication year - 2020
Publication title -
journal of breath research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.967
H-Index - 53
eISSN - 1752-7163
pISSN - 1752-7155
DOI - 10.1088/1752-7163/ab5d88
Subject(s) - exhaled breath condensate , chemistry , detection limit , repeatability , chromatography , medicine , asthma
Exposure to environmental and occupational particulate matter (PM) induces health effects on the cardio-pulmonary system. In addition, associations between exposure to PM and metabolic syndromes like diabetes mellitus or obesity are now emerging in the literature. Collection of exhaled breath condensate (EBC) is an appealing non-invasive technique to sample pulmonary fluids. This hypothesis-generating study aims to (1) validate an ion chromatography method allowing the robust determination of different metabolism-related molecules (lactate, formate, acetate, propionate, butyrate, pyruvate, nitrite, nitrate) in EBC; (2) apply this method to EBC samples collected from workers exposed to quartz (a known inflammatory particle), to soapstone (a less inflammatory particle than quartz), as well as to controls. A multi-compound standard solution was used to determine the linearity range, detection limit, repeatability and bias from spiked EBC. The biological samples were injected without further treatment into an ion chromatograph with a conductivity detector. RTube ® were used for field collection of EBC from 11 controls, 55 workers exposed to soapstone and 12 volunteers exposed to quartz dust. The analytical method used proved to be adequate for quantifying eight anions in EBC samples. Its sub-micromolar detection limits and repeatability, combined with a very simple sample preparation, allowed an easy and fast quantification of different glycolysis or nitrosative stress metabolites. Using multivariate discriminant analysis to maximize differences between groups, we observed a different pattern of anions with a higher formate/acetate ratio in the EBC samples for quartz exposed workers compared to the two other groups. We hypothesize that a modification of the metabolic signature could be induced by exposure to inflammatory particles like quartz and might be observed in the EBC via a change in the formate/acetate ratio.