z-logo
open-access-imgOpen Access
Improving timing performance of double-ended readout in TOF-PET detectors
Author(s) -
Guo Li,
Jinshou Tian,
P. Chen,
Stephen E. Derenzo,
Woon-Seng Choong
Publication year - 2020
Publication title -
journal of instrumentation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.741
H-Index - 84
ISSN - 1748-0221
DOI - 10.1088/1748-0221/15/01/p01003
Subject(s) - scintillator , detector , scintillation , full width at half maximum , optics , physics , silicon photomultiplier , lyso , time of flight , coincidence , photon , crystal (programming language) , parallax , computer science , medicine , alternative medicine , pathology , astronomy , programming language
Scintillation crystals of 20mm length or longer are needed for clinical time-of-flight positron emission tomography (TOF-PET) to ensure effective detection efficiency for gamma photons. However, the use of long crystals would deteriorate the key performance of TOF-PET detectors, time and spatial resolution, because of the variations in the travel times of the photons in crystals and the effects of parallax errors. In this work, we studied double-ended readout TOF-PET detectors based on coupling a long scintillation crystal to SiPMs at both ends for correcting the depth-dependent effects to improve the coincidence time resolution (CTR). In particular, we focused our attention to analyze timing performance using different correction methods, including trigger times of the individual photodetectors at both ends of the crystal, the simple average of the trigger times, and the weighted average based on the inverse variances of the depth-dependent corrected trigger times. For a 3 mm × 3 mm × 25mm unpolished lutetium fine silicate (LFS) crystal with double-ended readout and practical head-on irradiation, a CTR of 246ps FWHM can be achieved using depth-dependent timing-correction and weighted average time method compared to 280ps FWHM using the conventional simple average time method and 393ps FWHM using the conventional single-ended readout. The results show that the depth-dependent timing-correction and weighted average time method in double-ended readout can effectively correct for the trigger time variations in TOF-PET detector utilizing long unpolished crystals, resulting in an improvement in the CTR of as much as 37% compared to single-ended readout.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here