Reference Current Generation for Active Power Filtering in Single-Phase Power System
Author(s) -
Siew Ting Chew,
Yap Hoon,
Hilal Ahmad
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/2120/1/012024
Subject(s) - control theory (sociology) , power factor , reference frame , harmonics , computer science , total harmonic distortion , ripple , ac power , capacitive sensing , electric power system , harmonic , power (physics) , electronic engineering , engineering , frame (networking) , voltage , electrical engineering , telecommunications , physics , control (management) , artificial intelligence , quantum mechanics , operating system
The study presents a new proposed reference current generation algorithm based on the synchronous reference frame (SRF) conventional algorithm in single-phase power system for an active power filtering. Shunt active power filter (SAPF) is often used as it can mitigate harmonic currents in the AC networks due to its superiority in dynamic-state conditions. The reference current generation algorithm is the most important control algorithms to control SAPF as it has the simplest implementation features. A proposed STF-based fundamental component identifier (STF-FCI) algorithm is implemented for the major improvements such as the removal of the unnecessary cosine function to reduce complexity of algorithm, employment of self-tuning filter (STF) to extract accurate fundamental component and to generate a sinusoidal reference current. The purpose of developing STF-FCI algorithm is to replace low pass filter (LPF) with a mean as it can generate a fast and accurate fundamental reference current to operate the SAPF in reducing the harmonics content of the power system and provide a fast response time in the dynamic-state conditions. This paper is presented under both steady-state which is capacitive (RC) load or inductive (RL) load as well as dynamic condition where capacitive load change to inductive load. The performance of steady-state condition will be evaluated in terms of THD values, ripple factor, power factor and phase difference. Under dynamic-state condition, the dynamic speed will be evaluated to capture the speed of the amplitude change in nonlinear load in a period of time. MATLAB-Simulink is used to design and evaluate the proposed STF-FCI algorithm with mean algorithm and LPF algorithm for comparison purpose. The simulation results had shown the major improvement when THD values, ripple factor, power factor and phase difference are reduced. The response time of the changing load is shorter by using mean algorithm compare to LPF algorithm. The simulation results obtained proved success when the proposed STF-FCI algorithm using mean algorithm are much better than LPF algorithm in steady-state and dynamic conditions under two voltage conditions i.e. ideal and distorted voltage.