Determination of the anisotropic thermal conductivity of an aerogel-based plaster using transient plane source method
Author(s) -
Ali Karim,
Bijan AdlZarrabi,
Pär Johansson,
Angela Sasic Kalagasidis
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/2069/1/012030
Subject(s) - aerogel , thermal conductivity , thermal diffusivity , anisotropy , materials science , thermal , thermal transmittance , transient (computer programming) , composite material , thermal conductivity measurement , heat flow , composite number , thermal resistance , optics , thermodynamics , physics , computer science , operating system
Aerogel-based plasters are composite materials with declared thermal conductivities in the range of traditional insulating materials, i.e. 30-50 mW/(m·K). Based on the results from reported field measurements, aerogel-based plasters can significantly reduce the thermal transmittance of uninsulated walls. However, the in-situ measured thermal conductivities have sometimes been higher than the declared values measured in laboratory and in the main direction of the heat flow. Meanwhile, the anisotropic thermal performance of aerogel-based plasters, i.e., deviating thermal performance in the different directions of heat flow, has not been explored yet. The objective of this study is thus to evaluate the anisotropic thermal conductivity of an aerogel-based plaster. This is done in a set of laboratory measurements using the transient plane source method. Six identical and cubic samples with the dimensions of 10×10×10 cm 3 were paired two and two, creating three identical sample sets. In total, 360 measurements of thermal conductivity and thermal diffusivity, and 130 measurements for specific heat capacity were conducted. The results indicate a weak anisotropy of less than ±6.5 % between the three directions (x, y, z). Considering the accuracy of the selected measurement technique, better than ±5 %, supplementary measurements using another technique are recommended.