Development of three-in-one equipment for withstand voltage, partial discharge and dielectric loss
Author(s) -
Xin Su,
Shuai Liu,
Haiyang Liu,
Zhe Zheng,
Shi Qiu,
Yao Lu
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/2005/1/012230
Subject(s) - partial discharge , voltage , dielectric , materials science , dielectric loss , electrical engineering , dielectric withstand test , acoustics , power cable , power (physics) , engineering , composite material , physics , layer (electronics) , quantum mechanics
Many major accidents in domestic and foreign power grids were caused by cable defects, causing huge economic losses and adverse social impacts. At present, the three main tests for cable testing are withstand voltage test, dielectric loss measurement and partial discharge measurement, which require different equipment for testing, which is low in efficiency and time-consuming. Among them, the very-low frequency method is suitable for the withstand voltage test, and the damped oscillatory wave method is suitable for the measurement of dielectric loss and partial discharge. This paper is based on very-low frequency cosine square wave and damped oscillatory wave technology, implements technology integration, and realizes the three-in-one detection of withstand voltage, dielectric loss, and partial discharge for cable.