Realization of Low Cost Footwear Integrated Step-Counting Device for Health Monitoring System
Author(s) -
Aryan,
Poornima Mittal
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1998/1/012006
Subject(s) - comparator , realization (probability) , voltage , electrical engineering , cascade , piezoelectricity , volt , computer science , low voltage , sense (electronics) , electronic engineering , computer hardware , engineering , mathematics , statistics , chemical engineering
In this paper, a piezoelectric sensor is used to sense the pressure generated when steps are taken. The output voltage generated by the piezo electric sensor is passed through a cascade combination of two voltage comparators, (LM 358 AND 741), the output of which is HIGH(5V) when a piezoelectric sensor is pressed and the voltage across the sensor goes above the threshold. The output of the comparators is then fed to the counter circuit (implemented using 4026 IC), which counts the number of times the output is high/steps are taken. Finally, the output is exhibited on a 7-segment display common cathode display.