
Experimental Assessment of Gas Static Meters Under Different Operating Conditions
Author(s) -
Furio Cascetta,
Marcello Bondesan,
Marilena Musto,
Giuseppe Rotondo
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1868/1/012012
Subject(s) - natural gas , metre , environmental science , flow measurement , wet gas , sample (material) , petroleum engineering , engineering , waste management , mechanics , thermodynamics , physics , astronomy
This paper compares the metrological performance of a sample of commercial domestic/residential smart meters for natural gas (G4). In particular, the performance degradation of electronic static and dynamic gas meters has been evaluated. The sample was composed by ultrasonic gas meters, thermal mass meters and diaphragm gas meters. The tests, performed on the gas meters, reproduce the most severe operating conditions (i.e. filed test) such as the influence of the gas composition, the temperature difference between gas and meter, the gas humidity and the presence of dust in the gas. Furthermore, the meters have been undergo to some endurance tests such as start and stop and to the high flowrate runs.