z-logo
open-access-imgOpen Access
Study on abnormal vibration caused by foundation settlement of a 650MW unit
Author(s) -
Lyuzhou Ma
Publication year - 2021
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1748/6/062032
Subject(s) - settlement (finance) , foundation (evidence) , vibration , rubbing , unit (ring theory) , steam turbine , turbine , shutdown , structural engineering , engineering , forensic engineering , computer science , mechanical engineering , mathematics , physics , history , acoustics , nuclear engineering , archaeology , mathematics education , world wide web , payment
An unplanned shutdown occurred in a 650MW unit after one year of commercial operation. In the subsequent start-up, due to the excessive rubbing vibration, the unit tripped many times. During the overhaul inspection, it was found that the foundation of the steam turbine had large uneven settlement. Through taking proper maintenance measures, the vibration problem was successfully solved.