z-logo
open-access-imgOpen Access
A digital twin based on OpenFAST linearizations for real-time load and fatigue estimation of land-based turbines
Author(s) -
Emmanuel Branlard,
Jason Jonkman,
Scott Dana,
Paula Doubrawa
Publication year - 2020
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1618/2/022030
Subject(s) - turbine , wind power , computer science , torque , control theory (sociology) , kalman filter , offshore wind power , wind speed , instrumentation (computer programming) , thrust , tower , simulation , control engineering , engineering , mechanical engineering , physics , electrical engineering , control (management) , artificial intelligence , meteorology , thermodynamics , civil engineering , operating system
Monitoring a wind turbine requires intensive instrumentation, which would be too cost-prohibitive to deploy to an entire wind plant. This work presents a technique that uses readily available measurements to estimate signals that would otherwise require additional instrumentation. This study presents a digital twin concept with a focus on estimating wind speed, thrust, torque, tower-top position, and loads in the tower using supervisory control and data acquisition (SCADA) measurements. The model combines a linear state-space model obtained using OpenFAST linearizations, a wind speed estimator, and a Kalman filter algorithm that integrates measurements with the state model to perform state estimations. The measurements are: top acceleration, generator torque, pitch, and rotational speed. The article extends previous work that derived the linear state-space model using a different method. The new implementation, based on OpenFAST linearization capability, allows for a systematic extension of the method to more states, inputs, outputs, and to the offshore environment. Results from the two methods are compared, and the validation is made with additional measurements using the GE 1.5-MW turbine located at the National Renewable Energy Laboratory test site. Real-time damage equivalent loads of the tower bottom moment are estimated with an average accuracy of approximately 10%. Overall, the results from this proof of concept are encouraging, and further application of the model will be considered.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.