Design and analysis of heat exchanger (evaporator) type of staggered tube cross-flow as modified evaporator AC-Split
Author(s) -
Farel H. Napitupulu,
Fellix,
H V Sihombing
Publication year - 2020
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1542/1/012007
Subject(s) - evaporator , tube (container) , heat exchanger , materials science , inlet , flow (mathematics) , mechanics , thermal expansion valve , mechanical engineering , composite material , physics , engineering
This study aims to make and analysis a tube group type evaporator design alternately with crossing flow as a result of modification of split PK 1 evaporator AC and to evaporate the working fluid, namely R-22, to environmental so that it also simultaneously cools the room. The evaporator designed has a length of 26 cm, a width of 16 cm and a height of 84.2 cm, with a tube diameter of 6.35 mm, a tube length of 58 cm and as many as 25 passes, consisting of 5 rows and 5 columns with alternating positions, distance between tubes 15 mm vertically and horizontally. With this design, the evaporator reduce the temperature air inlet of 0.08.