Temperature distribution in microwave chamber using the phantom limb
Author(s) -
A. V. Badin,
G. E. Dunaevskii,
A. Yu. Nechaev
Publication year - 2020
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1499/1/012031
Subject(s) - imaging phantom , microwave , impulse (physics) , detector , radiation , optics , microwave power , biomedical engineering , materials science , physics , acoustics , medicine , quantum mechanics
This paper presents results of temperature distribution in the phantom limb under the influence of microwave radiation. Authors had been developed automated installation based on linear positioner and temperature detector for measuring thermal field distribution in phantom of human hand. It was shown that under the influence of impulse microwave radiation having a power of 40W at the phantom during 6 minutes leads to equable warming along longitudinal axis of phantom.