Study of the SiPM double component recovery time
Author(s) -
O. Bychkova,
A. Ilyin,
F. Kayumov,
P. Parygin,
D. Philippov,
E. Popova,
A. Stifutkin,
Sergey Vinogradov
Publication year - 2019
Publication title -
journal of physics. conference series
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.21
H-Index - 85
eISSN - 1742-6596
pISSN - 1742-6588
DOI - 10.1088/1742-6596/1390/1/012108
Subject(s) - silicon photomultiplier , pixel , upgrade , component (thermodynamics) , calorimeter (particle physics) , physics , computer science , optics , detector , operating system , scintillator , thermodynamics
The recovery time of the Hamamatsu SiPM linear assembly was measured. The assembly contains eight SiPMs of 2.8mm active area diameter; pixel size is 15xl5mkm 2 . The assembly is used for Phase1 upgrade in hadron calorimeter of the CMS experiment. Recovering process is found to depend on the number of the pixels fired and varied from 7 ±1 ns to 23 ± 3 ns for 50 Ohm readout impedance.