z-logo
open-access-imgOpen Access
Grading hypoxic-ischemic encephalopathy in neonatal EEG with convolutional neural networks and quadratic time–frequency distributions
Author(s) -
Sumit A. Raurale,
Geraldine B. Boylan,
Sean Mathieson,
William P. Marnane,
Gordon Lightbody,
John M. O’Toole
Publication year - 2021
Publication title -
journal of neural engineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.594
H-Index - 111
eISSN - 1741-2560
pISSN - 1741-2552
DOI - 10.1088/1741-2552/abe8ae
Subject(s) - electroencephalography , computer science , convolutional neural network , kappa , pattern recognition (psychology) , artificial intelligence , computation , frequency domain , quadratic equation , speech recognition , algorithm , medicine , mathematics , geometry , psychiatry , computer vision
Objective. To develop an automated system to classify the severity of hypoxic-ischaemic encephalopathy injury (HIE) in neonates from the background electroencephalogram (EEG). Approach . By combining a quadratic time–frequency distribution (TFD) with a convolutional neural network, we develop a system that classifies 4 EEG grades of HIE. The network learns directly from the two-dimensional TFD through 3 independent layers with convolution in the time, frequency, and time–frequency directions. Computationally efficient algorithms make it feasible to transform each 5 min epoch to the time–frequency domain by controlling for oversampling to reduce both computation and computer memory. The system is developed on EEG recordings from 54 neonates. Then the system is validated on a large unseen dataset of 338 h of EEG recordings from 91 neonates obtained across multiple international centres. Main results. The proposed EEG HIE-grading system achieves a leave-one-subject-out testing accuracy of 88.9% and kappa of 0.84 on the development dataset. Accuracy for the large unseen test dataset is 69.5% (95% confidence interval, CI: 65.3%–73.6%) and kappa of 0.54, which is a significant ( \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}$P\lt0.001$\end{document} P < 0.001) improvement over a state-of-the-art feature-based method with an accuracy of 56.8% (95% CI: 51.4%–61.7%) and kappa of 0.39. Performance of the proposed system was unaffected when the number of channels in testing was reduced from 8 to 2—accuracy for the large validation dataset remained at 69.5% (95% CI: 65.5%–74.0%). Significance. The proposed system outperforms the state-of-the-art machine learning algorithms for EEG grade classification on a large multi-centre unseen dataset, indicating the potential to assist clinical decision making for neonates with HIE.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom