Novel, clinically applicable method to measure step-width during the swing phase of gait
Author(s) -
Tomas Bäcklund,
Fredrik Öhberg,
Gustav Johansson,
Helena Grip,
Nina Sundström
Publication year - 2020
Publication title -
physiological measurement
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.674
H-Index - 101
eISSN - 1361-6579
pISSN - 0967-3334
DOI - 10.1088/1361-6579/ab95ed
Subject(s) - stride , gait , swing , gait analysis , simulation , physical medicine and rehabilitation , computer science , medicine , physics , acoustics
Objective : Step-width during walking is an indicator of stability and balance in patients with neurological disorders, and development of objective tools to measure this clinically would be a great advantage. The aim of this study was to validate an in-house-developed gait analysis system (Striton), based on optical and inertial sensors and a novel method for stride detection, for measuring step-width during the swing phase of gait and temporal parameters. Approach : The step-width and stride-time measurements were validated in an experimental setup, against a 3D motion capture system and on an instrumented walkway. Further, test-retest and day-to-day variability were evaluated, and gait parameters were collected from 87 elderly persons (EP) and four individuals with idiopathic normal pressure hydrocephalus (iNPH) before/after surgery. Main results : Accuracy of the step-width measurement was high: in the experimental setup mean error was 0.08 ± 0.25 cm (R = 1.00) and against the 3D motion capture system 0.04 ± 1.12 cm (R = 0.98). Test-retest and day-to-day measurements were equal within ±0.5 cm. Mean difference in stride time was −0.003 ± 0.008 s between Striton and the instrumented walkway. The Striton system was successfully applied in the clinical setting on individuals with iNPH, which had larger step-width (6.88 cm, n = 4) compared to EP (5.22 cm, n = 87). Significance : We conclude that Striton is a valid, reliable and wearable system for quantitative assessment of step-width and temporal parameters during gait. Initial measurements indicate that the newly defined step-width parameter differs between EP and patients with iNPH and before/after surgery. Thus, there is potential for clinical applicability in patients with reduced gait stability.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here