Improving depth-of-interaction resolution in pixellated PET detectors using neural networks
Author(s) -
Artem Zatcepin,
Marco Pizzichemi,
Andrea Polesel,
M. Pagai,
E. Auffray,
Sibylle Ziegler,
Negar Omidvari
Publication year - 2020
Publication title -
physics in medicine and biology/physics in medicine and biology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.312
H-Index - 191
eISSN - 1361-6560
pISSN - 0031-9155
DOI - 10.1088/1361-6560/ab9efc
Subject(s) - lyso , silicon photomultiplier , full width at half maximum , detector , resolution (logic) , image resolution , parallax , convolutional neural network , optics , scintillator , physics , artificial intelligence , computer science , artificial neural network , materials science
Parallax error is a common issue in high-resolution preclinical positron emission tomography (PET) scanners as well as in clinical scanners that have a long axial field of view (FOV), which increases estimation uncertainty of the annihilation position and therefore degrades the spatial resolution. A way to address this issue is depth-of-interaction (DOI) estimation. In this work we propose two machine learning-based algorithms, a dense and a convolutional neural network (NN), as well as a multiple linear regression (MLR)-based method to estimate DOI in depolished PET detector arrays with single-sided readout. The algorithms were tested on an 8× 8 array of 1.53× 1.53× 15 mm 3 crystals and a 4× 4 array of 3.1× 3.1× 15 mm 3 crystals, both made of Ce:LYSO scintillators and coupled to a 4× 4 array of 3× 3 mm 3 silicon photomultipliers (SiPMs). Using the conventional linear DOI estimation method resulted in an average DOI resolution of 3.76 mm and 3.51 mm FWHM for the 8× 8 and the 4× 4 arrays, respectively. Application of MLR outperformed the conventional method with average DOI resolutions of 3.25 mm and 3.33 mm FWHM, respectively. Using the machine learning approaches further improved the DOI resolution, to an average DOI resolution of 2.99 mm and 3.14 mm FWHM, respectively, and additionally improved the uniformity of the DOI resolution in both arrays. Lastly, preliminary results obtained by using only a section of the crystal array for training showed that the NN-based methods could be used to reduce the number of calibration steps required for each detector array.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here