Stereotactical fields applied in proton spot scanning mode with range shifter and collimating aperture
Author(s) -
Christian Bäumer,
Carolina Fuentes,
Martin S. Janson,
Aleksandar Matic,
Beate Timmermann,
Jörg Wulff
Publication year - 2019
Publication title -
physics in medicine and biology/physics in medicine and biology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.312
H-Index - 191
eISSN - 1361-6560
pISSN - 0031-9155
DOI - 10.1088/1361-6560/ab2ae7
Subject(s) - proton therapy , collimated light , aperture (computer memory) , optics , beam (structure) , scintillation , proton , monte carlo method , pencil beam scanning , materials science , range (aeronautics) , isocenter , physics , nuclear physics , laser , acoustics , statistics , mathematics , detector , imaging phantom , composite material
Some clinical indications require small fields with sharp lateral dose gradients, which is technically challenging in proton beam therapy. This holds especially true for low-range fields applied with the spot scanning technique, where large beam profiles entering from the beam-line or the insertion of range shifting blocks lead to large lateral gradients. We regard the latter case and solve it by shifting the range shifting block far upstream in conjunction with a collimating aperture close to the patient. The experiments of the current work are based on a commercial proton therapy treatment head designed for several delivery modes. In a research environment of the spot-scanning delivery mode a range shifter is inserted downstream of the scanning magnets in a slot which is usually employed only in a scattering delivery mode. This configuration is motivated by equations assuming a simple model of proton transport. In the experiments lateral dose planes are acquired with a scintillation screen and radiochromic films. Dose distributions are calculated with the Monte Carlo dose engine of the RayStation treatment planning system. We demonstrate that proton fields with 80%–20% lateral dose fall-off values between 1.4 mm and 4.0 mm can be achieved for water equivalent depths between 0 cm and 10 cm. The simulated lateral dose profiles agree with the experimental dose profiles. The sharpening of the field edges is set off by a broadening of the proton spots towards the center of the fields. This limits the clinical application mainly to small fields for which the distal and proximal conformality is of minor importance.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here