z-logo
open-access-imgOpen Access
Dose-optimised chest computed tomography for diagnosis of Coronavirus Disease 2019 (COVID-19) – Evaluation of image quality and diagnostic impact
Author(s) -
Andrea Steuwe,
Christin Rademacher,
Birte Valentin,
Marie-Helen Köhler,
Elisabeth Appel,
Verena Keitel,
Jörg Timm,
Gerald Antoch,
Joel Aissa
Publication year - 2020
Publication title -
journal of radiological protection
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.471
H-Index - 46
eISSN - 1361-6498
pISSN - 0952-4746
DOI - 10.1088/1361-6498/aba16a
Subject(s) - medicine , confidence interval , cohort , radiology , nuclear medicine , covid-19 , image quality , disease , infectious disease (medical specialty) , artificial intelligence , computer science , image (mathematics)
Objectives. The detection of Coronavirus Disease 2019 (COVID-19) by reverse transcription polymerase chain reaction (RT-PCR) has varying sensitivity. Computed tomography (CT) of the chest can verify infection in patients with clinical symptoms and a negative test result, accelerating treatment and actions to prevent further contagion. However, CT employs ionising radiation. The purpose of this study was to evaluate protocol settings, associated radiation exposure, image quality and diagnostic performance of a low-dose CT protocol in a university hospital setting. Materials and Methods . Chest CT examinations were performed on a single scanner (Somatom Definition Edge, Siemens Healthineers, Germany) in 105 symptomatic patients (60 male, 45 female). Images were evaluated with regard to protocol parameters, image quality, radiation exposure and diagnostic accuracy. Serial RT-PCR served as the standard of reference. Based on this reference standard sensitivity, specificity, positive and negative predictive values of CT with 95% confidence interval were calculated. Results . The mean effective dose was 1.3 ± 0.4 mSv (0.7–2.9 mSv) for the patient cohort (mean age 66.6 ± 16.7 years (19–94 years), mean body mass index (BMI) 26.6 ± 5.3 kg m −2 (16–46 kg/m 2 )). A sensitivity of 100 [95% CI: 82–100]%, a specificity of 78 [95% CI: 68–86]%, a positive predictive value of 50 [95% CI: 33–67]% and a negative predictive value of 100 [95% CI: 95–100]% were obtained. No COVID-19 diagnoses were missed by CT. Image noise did not strongly correlate with BMI or patient diameter and was rated as average. Conclusions . We presented a robust imaging procedure with a chest CT protocol for confident diagnosis of COVID-19. Even for an overweight patient cohort, an associated radiation exposure of only 1.3 ± 0.4 mSv was achieved with sufficient diagnostic quality to exclude COVID-19.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom