Homogeneity testing and quantitative analysis of manganese (Mn) in vitrified Mn-doped glasses by laser-induced breakdown spectroscopy (LIBS)
Author(s) -
V. K. Unnikrishnan,
Rajesh Nayak,
V. B. Kartha,
Santhosh Chidangil,
M. S. Sonavane,
R.G. Yeotikar,
M.L. Shah,
Gaurav Gupta,
B. M. Suri
Publication year - 2014
Publication title -
aip advances
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.421
H-Index - 58
ISSN - 2158-3226
DOI - 10.1063/1.4894535
Subject(s) - laser induced breakdown spectroscopy , materials science , spectroscopy , analytical chemistry (journal) , manganese , elemental analysis , emission spectrum , atomic emission spectroscopy , scanning electron microscope , laser , energy dispersive x ray spectroscopy , certified reference materials , spectral line , optics , plasma , chemistry , inductively coupled plasma , detection limit , metallurgy , physics , quantum mechanics , organic chemistry , chromatography , astronomy , composite material
Laser-induced breakdown spectroscopy (LIBS), an atomic emission spectroscopy method, has rapidly grown as one of the best elemental analysis techniques over the past two decades. Homogeneity testing and quantitative analysis of manganese (Mn) in manganese-doped glasses have been carried out using an optimized LIBS system employing a nanosecond ultraviolet Nd:YAG laser as the source of excitation. The glass samples have been prepared using conventional vitrification methods. The laser pulse irradiance on the surface of the glass samples placed in air at atmospheric pressure was about 1.7×109 W/cm2. The spatially integrated plasma emission was collected and imaged on to the spectrograph slit using an optical-fiber-based collection system. Homogeneity was checked by recording LIBS spectra from different sites on the sample surface and analyzing the elemental emission intensities for concentration determination. Validation of the observed LIBS results was done by comparison with scanning electron microscope- energy dispersive X-ray spectroscopy (SEM-EDX) surface elemental mapping. The analytical performance of the LIBS system has been evaluated through the correlation of the LIBS determined concentrations of Mn with its certified values. The results are found to be in very good agreement with the certified concentrations

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom