Open Access
Metrological performance of diaphragm gas meters with different use age
Author(s) -
Li Xia,
Deng Xiaoyuan,
Zhang Song,
Zhan Jiao,
Wu Li
Publication year - 2019
Publication title -
the journal of engineering
Language(s) - English
Resource type - Journals
ISSN - 2051-3305
DOI - 10.1049/joe.2018.9164
Subject(s) - metrology , diaphragm (acoustics) , adaptability , weighting , duration (music) , engineering , statistics , electrical engineering , mathematics , acoustics , physics , economics , management , loudspeaker
According to the current legal metrological regulation of diaphragm gas meter, domestic gas meters in China are required to pass mandatory initial verification at 20°C, and then a 10 years' legal duration is allowed without any subsequent or in‐service verifications. Here, experimental study has been implemented to investigate the metrological performance and temperature adaptability of old diaphragm gas meters with different use age. Through the introduction of weighting factors, weighted mean errors are calculated to analyse the correlation between the indication errors of gas meters and their use age, as well as the relationship between the indication errors and test temperatures. Experimental results indicate that the use age of gas meters has negligible influence on their metrological performance during the 10 years' legal duration. However, the indication errors worsen as temperature varies.