z-logo
open-access-imgOpen Access
Performance of SMES system with non‐linear dynamic evolution control approach for pulsed power load compensation
Author(s) -
Penthia Trilochan,
Panda Anup Kumar,
Patnaik Nishant,
Mohanty Pratap Ranjan
Publication year - 2020
Publication title -
iet generation, transmission and distribution
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.92
H-Index - 110
eISSN - 1751-8695
pISSN - 1751-8687
DOI - 10.1049/iet-gtd.2019.1880
Subject(s) - control theory (sociology) , superconducting magnetic energy storage , controller (irrigation) , harmonic , pid controller , pulse width modulation , compensation (psychology) , voltage source , computer science , power (physics) , control system , voltage , energy storage , engineering , control (management) , control engineering , temperature control , electrical engineering , physics , electromagnetic coil , psychology , agronomy , superconducting magnet , quantum mechanics , artificial intelligence , biology , psychoanalysis
Superconducting magnetic energy storage (SMES) system is one of the efficient pulsed power compensators. Its response to the load fluctuations is faster and competent. This study proposes a non‐linear dynamic evolution control (NDEC) approach for SMES system. The control approach is implemented to regulate the error of three‐phase compensating current and DC‐link voltage. The control functions required for voltage source inverter (VSI) and bi‐directional DC–DC converter of the SMES system are derived using the NDEC control approach. A proportional–integral (PI) controller is replaced by the NDEC in the inner loop of a traditional pulse‐width‐modulation control strategy of VSI for the quick response and effective energy exchange. The elementary idea of implementing NDEC is to govern the system dynamics by maintaining a zero‐error state irrespective of load uncertainties quickly. Detrimental high rating stress on the system due to pulsed power load is substantially reduced with the proposed NDEC strategy. Source current is maintained almost balanced and harmonic‐free in order to ensure a quality and reliable supply to surrounding loads. The variation in source current is drastically reduced from 260 to 6% using the proposed system. Moreover, a comparative study between PI and NDEC‐based control scheme is presented using MATLAB simulation and experimental results.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here