Coordinative real‐time sub‐transmission volt–var control for reactive power regulation between transmission and distribution systems
Author(s) -
Ke Xinda,
Samaan Nader,
Holzer Jesse,
Huang Renke,
Vyakaranam Bharat,
Vallem Mallikarjuna,
Elizondo Marcelo,
Lu Ning,
Zhu Xiangqi,
Werts Brant,
Nguyen Quan,
Huang Alex,
Makarov Yuri V.
Publication year - 2019
Publication title -
iet generation, transmission and distribution
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.92
H-Index - 110
eISSN - 1751-8695
pISSN - 1751-8687
DOI - 10.1049/iet-gtd.2018.5850
Subject(s) - ac power , distributed generation , transmission (telecommunications) , power control , volt , voltage , computer science , control theory (sociology) , electric power transmission , transmission system , volt ampere reactive , engineering , power (physics) , voltage optimisation , electrical engineering , renewable energy , control (management) , physics , quantum mechanics , artificial intelligence
This study introduces a new approach for coordinating volt–var control (VVC) between sub‐transmission and distribution systems through optimal reactive power dispatch of distributed energy resources (DERs) that are aggregated as virtual power plants (VPPs). At the sub‐transmission level, shunt devices and the reactive power provided by the VPPs are coordinated and optimised using a VVC algorithm with weighted sum of multiple objects that include minimising voltage deviations from desirable levels at load buses, minimising loses, minimising solar curtailment, minimising demand response usage and minimising mechanical switching of shunt elements. The algorithm runs every 5 min and is solved using the AC optimal power flow technique. At the distribution level, each VPP runs a distribution VVC algorithm to dispatch reactive power from DERs. The goal of the VPP reactive power control is to meet sub‐transmission service requirements while satisfying all the constraints at the distribution side. Each VPP updates its reactive power capability every 5 min to allow the sub‐transmission controller to formulate the optimisation problem for the next dispatch interval. The proposed tool is simulated on a Duke Energy Carolina system to demonstrate the capability of providing voltage support by dispatching reactive power of DERs as a VPP.