Digital‐domain dual‐calibration for single‐ended successive approximation register ADCs
Author(s) -
Lin Zhilun,
Wu Jianhui,
Chen Chao
Publication year - 2015
Publication title -
electronics letters
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.375
H-Index - 146
eISSN - 1350-911X
pISSN - 0013-5194
DOI - 10.1049/el.2015.1180
Subject(s) - successive approximation adc , calibration , converters , shaping , spurious relationship , computer science , distortion (music) , capacitor , electronic engineering , spurious free dynamic range , noise (video) , dynamic range , mathematics , artificial intelligence , engineering , voltage , electrical engineering , cmos , amplifier , statistics , machine learning , image (mathematics)
A digital‐domain dual‐calibration for single‐ended successive approximation register analogue‐to‐digital converters (SAR ADCs) is presented. The dual‐calibration combines digital error correction with capacitor mismatch calibration to compensate the decision errors and improve capacitor matching. Simulation results show that the proposed digital‐domain dual‐calibration technique can significantly improve signal‐to‐noise‐and‐distortion and spurious‐free dynamic range for the single‐ended SAR ADC.