z-logo
Premium
Ultracompact, Completely Implantable Permanent Use Electromechanical Ventricular Assist Device and Total Artificial Heart
Author(s) -
Honda Nobuhisa,
Inamoto Taro,
Nogawa Masamichi,
Takatani Setsuo
Publication year - 1999
Publication title -
artificial organs
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.684
H-Index - 76
eISSN - 1525-1594
pISSN - 0160-564X
DOI - 10.1046/j.1525-1594.1999.06327.x
Subject(s) - artificial heart , actuator , materials science , stroke (engine) , biomedical engineering , ventricular assist device , rotational speed , medicine , cardiology , mechanical engineering , electrical engineering , heart failure , engineering
An ultracompact, completely implantable permanent use electromechanical ventricular assist device (VAD) and total artificial heart (TAH) intended for 50–60 kg size patients have been developed. The TAH and VAD share a miniature electromechanical actuator that comprises a DC brushless motor and a planetary roller screw. The rotational force of the motor is converted into the rectilinear force of the roller screw to actuate the blood pump. The TAH is a one piece design with left and right pusher plate type blood pumps sandwiching an electromechanical actuator. The VAD is one half of the TAH with the same actuator but a different pump housing and a backplate. The blood contacting surfaces, including those of the flexing diaphragm and pump housing, of both the VAD and TAH were made of biocompatible polyurethane. The diameter, thickness, volume, and weight of the VAD are 90 mm, 56 mm, 285 cc, and 380 g, respectively, while those of the TAH are 90 mm, 73 mm, 400 cc, and 440 g, respectively. The design stroke volume of both the VAD and TAH is 60 cc with the stroke length being 12 mm. The stroke length and motor speed are controlled solely based on the commutation signals of the motor. An in vitro study revealed that a maximum pump flow of 7.5 L/min can be obtained with a pump rate of 140 bpm against a mean afterload of 100 mm Hg. The power requirement ranged from 4 to 6 W to deliver a 4–5 L/min flow against a 100 mm Hg afterload with the electrical‐to‐hydraulic efficiency being 19–20%. Our VAD and TAH are the smallest of the currently available devices and suitable for bridge to transplant application as well as for permanent circulatory support of 50–60 kg size patients.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here