z-logo
Premium
Evaluation of a Dual Chamber Implantable Cardioverter Defibrillator for the Treatment of Atrial and Ventricular Arrhythmias
Author(s) -
BORIANI GIUSEPPE,
WOLLMANN CHRISTIAN,
BIFFI MAURO,
KÜHL MARTIN,
SCHUCHERT ANDREAS,
SPERZEL JOHANNES,
STILLER SASCHA,
GASPARINI GIANNI,
BÖCKER DIRK
Publication year - 2003
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1046/j.1460-9592.2003.00072.x
Subject(s) - medicine , cardiology , atrial fibrillation , shock (circulatory) , implantable cardioverter defibrillator , single chamber , coronary sinus , atrial tachycardia , catheter ablation
BORIANI, G., et al .: Evaluation of a Dual Chamber Implantable Cardioverter Defibrillator for the Treatment of Atrial and Ventricular Arrhythmias.Eighty‐nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty‐two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AF. The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was2.41 ± 0.64  secondswith enhancements On and2.29 ± 0.47with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of1.9 ± 1.4  J. (range 0.5–5 J). During follow‐up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J. (PACE 2003; 26[Pt. II]:461–465)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here