Incidence and Predictors of Pacemaker Dysfunction with Unipolar Ventricular Lead Configuration. Can We Identify Patients Who Benefit from Bipolar Electrodes?
Author(s) -
WIEGAND UWE K. H.,
BODE FRANK,
BONNEMEIER HENDRIK,
TÖLG RALPH,
PETERS WERNER,
KATUS HUGO A.
Publication year - 2001
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1046/j.1460-9592.2001.01383.x
Subject(s) - medicine , cardiology , lead (geology) , artificial cardiac pacemaker , incidence (geometry) , heart failure , hazard ratio , confidence interval , physics , geomorphology , optics , geology
WIEGAND, U.K.H., et al. : Incidence and Predictors of Pacemaker Dysfunction with Unipolar Ventricular Lead Configuration. Can We Identify Patients Who Benefit from Bipolar Electrodes? Unipolar ventricular leads were implanted in a considerable percentage of pacemaker recipients. There is little information on incidence and risk factors for unipolar pacemaker dysfunction using modern lead designs. Included in a cross‐sectional analysis were 682 patients who fulfilled the following criteria: chronically implanted bipolar ventricular leads (> 1 year), intraoperative stimulation threshold < 1.0 V/0.5 ms, and potential amplitude > 6 mV. Incidences of chest wall stimulation (CWS) at an output of twice the amplitude threshold and of myopotential oversensing (MPO) at a sensitivity of half the sensing threshold were assessed. Energy (0.60 [0.72] vs 0.63 [0.81] μJ) and sensing thresholds (8.31 [3.18] mV vs 8.47 [3.47] mV) did not differ between uni‐ and bipolar modes. While all pacemakers worked properly during bipolar configuration, malfunctions were observed in 5.9% of patients during unipolar configuration ( CWS = 1.9%, MPO = 4.2% ). Patient age > 76 years (hazard ratio HR 8.2; P < 0.001), heart failure ≥ NYHA Class II (HR 3.8; P < 0.001), and an antiarrhythmic therapy with Class I or III drugs ( HR 3.3; P = 0.002 ) were independently associated with the occurrence of unipolar pacemaker dysfunction. Use of steroid‐eluting leads reduced the probability of pacemaker dysfunction ( HR 0.45; P = 0.03 ). Risk factors for unipolar ventricular pacemaker malfunction were higher age, heart failure, and antiarrhythmic drug therapy. Particularly in these patients, use of bipolar ventricular leads is beneficial.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here