Premium
Atrioventricular Interval Optimization in the Right Atrial Appendage and Interatrial Septum Pacing: A Comparison Between Echo and Peak Endocardial Acceleration Measurements
Author(s) -
PADELETTI LUIGI,
PORCIANI MARIA CRISTINA,
RITTER PHILIPPE,
MICHELUCCI ANTONIO,
COLELLA ANDREA,
PIERAGNOLI PAOLO,
COSTOLI ALESSANDRO,
CIAPETTI CRISTINA,
SABINI ALESSANDRA,
DEMARCHI GABRIELE,
GILLIOMEINA LAURA,
GAGGINI GUIDO,
GENSINI GIAN FRANCO
Publication year - 2000
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1046/j.1460-9592.2000.01618.x
Subject(s) - interatrial septum , medicine , cardiology , atrial fibrillation , appendage , anatomy , left atrium
PADELETTI, et al. : Atrioventricular Interval Optimization in the Right Atrial Appendage and Interatrial Septum Pacing: A Comparison Between ECHC and Peak Endocardial Acceleration. Interatrial septum pacing (IASP) reduces interatrial conduction time and consequently may interfere with atrioventricular delay (AVD) optimization. We studied 14 patients with an implanted BEST Living system device able to measure peak endocardial acceleration (PEA) signal. The aims of our study were to compare the (1) optimal AVD (OAVD) in right atrial appendage pacing (RAAP) and IASP, and (2) OAVD derived by the PEA signal versus OAVD derived by Echo/Doppler evaluation of the left ventricular filling time (LVFT) and cardiac output (CO). Measurements were performed in DDD VDD modes Eight patients (group A) had RAAP and six patients (group B) had IASP. In group A, OAVD measured by LVFT, CO, and PEA was 185 ± 23 ms , 177 ± 19 ms , and 192 ± 23 ms in DDD and 147 ± 19 ms , 135 ± 27 ms , and 146 ± 20 ms in VDD, respectively. OAVD measured by LVFT, CO, and PEA was significantly longer in DDD mode than in VDD ( P < 0.01, P < 0.01, P < 0.001 ). In group B, OAVD measured by LVFT, CO, and PEA was 116 ± 19 ms , 113 ± 10 ms , and 130 ± 30ms in DDD and 106 ± 16 ms , 96 ± 15 ms , and 108 ± 26 ms in VDD, respectively. No statistical differences were observed between DDD and VDD. Significant correlations between OAVDs PEA derived and OAVDs LVFT and CO derived were observed ( r = 0.71, r = 0.69, respectively ). When new techniques of atrial stimulation, as IASP, are used an OAVD shorter and similar in VDD and DDD has to be considered. The BEST Living system could provide a valid method to ensure, in every moment, the exact required OAVD to maximize atrial contribution to CO.