z-logo
Premium
Human duodenal phase III migrating motor complex activity is predominantly antegrade, as revealed by high‐resolution manometry and colour pressure plots
Author(s) -
Andrews J. M.,
O'donovan D. G.,
Hebbard G. S.,
Malbert C. H.,
Doran S. M.,
Dent J.
Publication year - 2002
Publication title -
neurogastroenterology and motility
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.489
H-Index - 105
eISSN - 1365-2982
pISSN - 1350-1925
DOI - 10.1046/j.1365-2982.2002.00337.x
Subject(s) - duodenum , peristalsis , migrating motor complex , antrum , anatomy , high resolution manometry , medicine , stomach , esophagus , achalasia
  Late phase III migrating motor complex activity has been said to be primarily retroperistaltic but has not been assessed with high resolution manometry or three‐dimensional colour pressure plots (pressure/time/distance). Duodenal phase III was examined in healthy young volunteers (seven male, two female) with a 20‐lumen assembly. With the most proximal sidehole in the distal antrum, after a 4.5‐cm interval 18 sideholes at 1.5‐cm intervals spanned the duodenum with a final sidehole 3 cm beyond. Fasting pressures were recorded until phase III occurred. Comparisons were made between proximal (P) and distal (D) duodenum during early (E) (first 0.5–1 min) and late (L) (last 0.5–1 min) phase III. With colour pressure analysis, 121 of 180 pressure wave (PW) sequences were purely antegrade, two purely retrograde and 57 bidirectional. Ten of fifty‐seven bidirectional PW sequences were complex, branching to become two separate sequences. Bidirectional sequences occurred more frequently in late than early phase III (L 43 vs. E 14 of 57), but their occurrence did not differ between proximal and distal duodenum (P31 vs. D 24 of 57). Antegrade propagation velocity was faster in late compared with early phase III (L 28.50 vs. E 17.05 mm s −1 ; P = 0.006), but did not differ between proximal and distal duodenum. Colour pressure analysis also indicated an intermittent segmental pattern to phase III, with each subject exhibiting a change in velocity or direction, or a relative failure of peristalsis somewhere along the duodenum during part of phase III. Duodenal phase III is not homogenous and, in contrast with previous studies, does not primarily constitute a retroperistaltic pump. Colour pressure analysis is useful in interpreting intraluminal pressure profiles and may improve the sensitivity and specificity of clinical studies.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here