Impact of hemodialysis duration on the removal of uremic retention solutes
Author(s) -
Sunny Eloot,
Wim Van Biesen,
Annemieke Dhondt,
H. Van de Wynkele,
Griet Glorieux,
P. Verdonck,
Raymond Vanholder
Publication year - 2007
Publication title -
kidney international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.499
H-Index - 276
eISSN - 1523-1755
pISSN - 0085-2538
DOI - 10.1038/sj.ki.5002750
Subject(s) - hemodialysis , uremia , uremic toxins , medicine , duration (music) , chemistry , urology , intensive care medicine , chromatography , art , literature
Several studies have stressed the importance of dialysis time in the removal of uremic retention solutes. To further investigate this, nine stable chronic hemodialysis patients were dialyzed for 4, 6, or 8 h processing the same total blood and dialysate volume by the Genius system and high-flux FX80 dialyzers. Inlet blood and outlet dialysate were analyzed for urea, creatinine, phosphorus, and beta2-microglobulin at various times. Total solute removal, dialyzer extraction ratios, and total cleared volumes were significantly larger during prolonged dialysis for urea, creatinine, phosphorus, and beta2-microglobulin. Reduction ratios increased progressively, except for phosphate and beta2-microglobulin, where the ratios remained constant after 2 h. In contrast, no significant difference was found for the reduction ratios of all solutes and Kt/V(urea) between the three different sessions. With longer dialyses, solutes are efficiently removed from the deeper compartments of the patient's body. Our study shows that care must be taken when using Kt/Vurea or reduction ratios as the only parameters to quantify dialysis adequacy.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom