z-logo
open-access-imgOpen Access
BRAVO I: A pilot study of vascular brachytherapy in polytetrafluoroethylene dialysis access grafts
Author(s) -
Sanjay Misra,
R Bonan,
Timothy A. Pflederer,
Prabir RoyChaudhury,
for the BRAVO I Investigators
Publication year - 2006
Publication title -
kidney international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.499
H-Index - 276
eISSN - 1523-1755
pISSN - 0085-2538
DOI - 10.1038/sj.ki.5001869
Subject(s) - polytetrafluoroethylene , medicine , brachytherapy , peritoneal dialysis , vascular access , dialysis , surgery , urology , hemodialysis , radiation therapy , materials science , metallurgy
Hemodialysis vascular access dysfunction owing to stenosis and thrombosis in polytetrafluoroethylene dialysis access grafts is a huge clinical problem for which there are currently no long lasting durable therapies. Vascular brachytherapy has been used successfully for the prevention of coronary restenosis following angioplasty and stent placement. The Beta Radiation for Treatment of Arterial-Venous Graft Outflow I study was a pilot study of vascular brachytherapy in hemodialysis patients with patent but dysfunctional grafts. Twenty-five patients were randomized to receive either radiation therapy (a single dose of 18.4 Gy) or sham radiation, following angioplasty. The primary efficacy end point of the study was target lesion primary patency at 6 months. The primary safety end point was a composite of death, emergency surgery on the graft, venous rupture, or aneurysm formation. Forty-two percent of the radiated grafts achieved the target lesion primary patency end point at 6 months as compared to 0% of the control group (P = 0.015), but this did not translate into an improvement in secondary patency at either 6 or 12 months. Radiation therapy was found to be safe in the setting of hemodialysis vascular access dysfunction. Our results suggest that vascular brachytherapy is an intervention that is worthy of further examination in the setting of non-thrombosed dialysis access grafts.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom