Both residual renal and dialytic clearance confer to the total solute clearance in dialysis patients. Dialytic clearances of the middle molecule beta-microglobulin (beta(2)M) and the protein-bound solute p-cresol (pcr) are generally believed to be higher with peritoneal dialysis (PD) as compared to hemodialysis (HD). Supportive data, however, are lacking. We performed a single-center cross-sectional observational study including 70 unselected patients treated with either high-flux HD (n=20) or PD (n=50). Mid-day serum levels (PD) and time-averaged concentrations (HD) of the water-soluble solutes urea nitrogen, creatinine and phosphate, the middle molecule beta(2)M, and the protein-bound solute pcr were determined. Dialytic solute clearances (l/week/1.73 m(2)) were calculated from total dialysate collection during the mid-week session in HD and 24 h dialysate collection in PD. Renal clearances were calculated for each of the respective solutes from a timed urine collection. Total clearances were obtained by summation. HD delivered significantly higher clearances of all retention solutes studied. This superiority was especially pronounced for pcr (30.9+/-62.7 vs 4.4+/-2.3, HD vs PD, P<0.0001) and beta(2)M (28.6+/-6.6 vs 5.8+/-3.1, HD vs PD, P<0.0001). Renal clearances, conversely, were significantly higher in patients on PD. Serum levels of all solutes but pcr were significantly lower in HD than in PD. Both a higher residual renal function and a lower generation rate contribute to the lower pcr levels in PD. In conclusion, superior dialytic clearance of both water-soluble solutes, beta(2)M, and pcr is achieved by high-flux HD as compared to PD.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom