Detection limit of methods to assess fluid status changes in dialysis patients
Author(s) -
Matthias Kraemer,
Christiane Rode,
V. Wizemann
Publication year - 2006
Publication title -
kidney international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.499
H-Index - 276
eISSN - 1523-1755
pISSN - 0085-2538
DOI - 10.1038/sj.ki.5000286
Subject(s) - medicine , peritoneal dialysis , blood volume , body fluid , inferior vena cava , bolus (digestion) , extracellular fluid , urology , nuclear medicine , chemistry , biochemistry , extracellular
Technical systems for an accurate and practicable fluid management of dialysis patients are urgently needed, since current clinical methods are partially subjective, imprecise, and time consuming. Such new systems should not only allow the determination of the target normohydration weight, but also must be able to detect clinically relevant changes in fluid volume ( approximately 1 l). This study focuses on the systematic analysis of the detection limit of several candidate methods for fluid management. In a cohort of 16 new dialysis patients, several candidate methods were applied in parallel during each treatment of the initial weight reduction phase: the measurement of vena cava diameter (VCD), vena cava collapsibility index (CI), the blood volume drop during an ultrafiltration (UF) bolus (Deltarelative blood volume (RBV)-), the rebound after the UF bolus (DeltaRBV+), and the extracellular fluid volume determined with whole body bioimpedance spectroscopy (BIS). A clinical reference method was used to manage the fluid status of patients. All methods showed significant correlations with predialysis weight. The detection limits W(lim) of candidate methods for changes in fluid status were assessed as W(lim)=0.87 kg+/-0.64 kg (BIS), 1.74 kg+/-1.56 kg (VCD), 2.3 kg+/-1.0 kg (DeltaRBV-), 7.4 kg+/-8.5 kg (CI), 40 kg+/-108 kg (DeltaRBV+). Only BIS shows a satisfactorily low detection limit W(lim), whereas W(lim) was rated as critical for the VCD and DeltaRBV- methods, and as unacceptable for the CI and DeltaRBV+ methods. Bioimpedance spectroscopy appears to be the most promising method for a practical fluid management system in dialysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom