z-logo
open-access-imgOpen Access
Reduction in urea distribution volume over time in clinically stable dialysis patients
Author(s) -
Salvatore Di Filippo,
Simeone Andrulli,
S. Mangano,
Ivano Baragetti,
A. Masa,
Giacomo Di Filippo,
Carlo Mura,
J. Nachtigal,
M Baruffaldi,
Francesco Barbisoni,
Raffaella Cravero,
S Agliata,
Karen Amar,
Pietro Faranna,
Francesco Locatelli
Publication year - 2006
Publication title -
kidney international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.499
H-Index - 276
eISSN - 1523-1755
pISSN - 0085-2538
DOI - 10.1038/sj.ki.5000149
Subject(s) - dialysis , reduction (mathematics) , urea , medicine , volume (thermodynamics) , urology , distribution (mathematics) , intensive care medicine , cardiology , chemistry , biochemistry , mathematics , thermodynamics , mathematical analysis , physics , geometry
We have previously shown that, assuming urea distribution volume (V) remains constant for 1 month, ionic dialysance (ID) allows the dialysis dose to be calculated without the need for blood sampling. The aim of this multicenter study was to verify whether the assumption of a constant V can be extended to 1 year. In clinically stable patients receiving thrice-weekly hemodialysis at 13 dialysis centers, V and Kt/V were assessed during three dialysis sessions at baseline and 1 year later using ID as dialyzer urea clearance and the single-pool urea kinetic model. Baseline albumin, hemoglobin, and C reactive protein were prespecified covariates for predicting the change in V over time. Of the 52 enrolled patients, 40 (25 males; age 63.0+/-13.5 years) completed the study. Baseline end-dialysis body weight (62.4+/-13.7 kg) showed a non-significant 1% reduction during follow-up (-0.6+/-2.8 kg; P=0.175), whereas V significantly decreased from 29.0+/-6.8 to 27.4+/-6.0 l (-1.6+/-3.0 l or 4.5%; P=0.002). The reduction in V was greater when baseline albumin was lower (P=0.001) and baseline V was higher (P=0.005). The single-pool K(t)/V calculated using baseline V underestimated the actual value by 0.07+/-0.16 (P=0.008). The slight underestimate of Kt/V during follow-up suggests that annual V evaluations may be sufficient for dialysis dose quantification as the only risk is underestimating the actually delivered dialysis dose. However, the relationship between baseline albumin and the reduction in V over time may have nutritional value, and suggests more frequent V evaluations.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom