Premium
Use of cerebral oximetry to detect and manage cerebral desaturation with a rapidly expanding neck hematoma
Author(s) -
Akça O.,
Sessler D. I.
Publication year - 2002
Publication title -
acta anaesthesiologica scandinavica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.738
H-Index - 107
eISSN - 1399-6576
pISSN - 0001-5172
DOI - 10.1034/j.1399-6576.2002.460521.x
Subject(s) - medicine , hematoma , anesthesia , glasgow coma scale , surgery
Background: We report a case in which cerebral oximetry was used to successfully demonstrate when cerebral oxygen saturation is dangerously low. Methods: In a 60‐year‐old‐man with end‐stage multiple myeloma and hyperviscosity syndrome, a rapidly expanding hematoma developed after insertion of an internal jugular central venous catheter. As the hematoma expanded, the patient became lethargic and disoriented (Glasgow Coma Score of E2/M4‐5/V2‐ETT). His platelet count was 17,000.mm −3 , hemoglobin was 4.5 g/dl, partial thromboplastin time was 51 s, and his international ratio was 1.7. Although carotid pulses became unpalpable, blood pressure and heart rate remained stable. Cerebral oximeter probes positioned on the patient's forehead showed that cerebral oxygen saturation was 22–26% bilaterally. The surgery team was advised to surgically evacuate the hematoma. Results: The hematoma was evacuated and a small needle hole in the right internal jugular vein adjacent to the central‐venous catheter was found and repaired. Cerebral oxygen saturation increased to 56–58% within 1 h and stabilized near 60%. The patient awoke with normal cognitive function. Conclusion: This case demonstrates how cerebral oximetry can be used to give quantitative evidence of cerebral hypoxia, thus showing that immediate surgical intervention is necessary.