Testing and parameterizing a conceptual model for solute transport in a fractured granite using multiple tracers in a forced‐gradient test
Author(s) -
Reimus Paul,
Pohll Greg,
Mihevc Todd,
Chapman Jenny,
Haga Marc,
Lyles Brad,
Kosinski Sean,
Niswonger Rich,
Sanders Peter
Publication year - 2003
Publication title -
water resources research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.863
H-Index - 217
eISSN - 1944-7973
pISSN - 0043-1397
DOI - 10.1029/2002wr001597
Subject(s) - tracer , sorption , diffusion , matrix (chemical analysis) , retardation factor , radionuclide , geology , soil science , mineralogy , materials science , chemistry , thermodynamics , physics , adsorption , composite material , chromatography , organic chemistry , column chromatography , nuclear physics , quantum mechanics
A cross‐hole tracer test involving the simultaneous injection of two nonsorbing solute tracers with different diffusion coefficients (bromide and pentafluorobenzoate) and a weakly sorbing solute tracer (lithium ion) was conducted in a fractured granite near an underground nuclear test cavity in central Nevada. The test was conducted to (1) test a conceptual radionuclide transport model for the site and (2) obtain transport parameter estimates for predictive modeling. The differences between the responses of the two nonsorbing tracers (when normalized to injection masses) are consistent with a dual‐porosity transport system in which matrix diffusion is occurring. The large concentration attenuation of the sorbing tracer relative to the nonsorbing tracers suggests that diffusion occurs primarily into matrix pores, not simply into stagnant water within the fractures. The relative responses of the tracers at late times suggest that the diffusion‐accessible matrix pore volume is possibly limited to only half the total volume of the flow system, implying that the effective retardation factor due to matrix diffusion may be as small as 1.5 for nonsorbing solutes in the system. The lower end of the range of possible sorption K d values deduced from the lithium response is greater than the upper 95% confidence bound of K d values measured in laboratory sorption tests using crushed granite from the site. This result suggests that the practice of using laboratory sorption data in field‐scale transport predictions of cation‐exchanging radionuclides, such as 137 Cs + and 90 Sr ++ , should be conservative for the SHOAL site.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here