z-logo
open-access-imgOpen Access
Spheroid-3D and Monolayer-2D Intestinal Electrochemical Biosensor for Toxicity/Viability Testing: Applications in Drug Screening, Food Safety, and Environmental Pollutant Analysis
Author(s) -
Evangelia Flampouri,
Shahzad Imar,
Kieran OConnell,
Baljit Singh
Publication year - 2019
Publication title -
acs sensors
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.055
H-Index - 57
ISSN - 2379-3694
DOI - 10.1021/acssensors.8b01490
Subject(s) - viability assay , cytotoxicity , toxicity , chemistry , resazurin , biosensor , in vivo , in vitro toxicology , biochemistry , chromatography , pharmacology , cell , in vitro , biology , microbiology and biotechnology , organic chemistry
The rise of three-dimensional cell culture systems that provide in vivo-like environments for pharmaco-toxicological models has prompted the need for simple and robust viability assays suitable for complex cell architectural structures. This study addresses that challenge with the development of an in vitro enzyme based electrochemical sensor for viability/cytotoxicity assessment of two-dimensional (2D) monolayer and three-dimensional (3D) spheroid culture formats. The biosensor measures the cell viability/toxicity via electrochemical monitoring of the enzymatic activity of nonspecific esterases of viable cells, through the hydrolysis of 1-naphthyl acetate to 1-naphthol. The proposed sensor demonstrated strong correlation ( r = 0.979) with viable cell numbers. Furthermore, the model intestinal toxicants diclofenac (DFC, pharmaceutical), okadaic acid (OA, food-safety), and mancozeb (MZB, environmental) were used for the functional evaluation of the proposed sensor using 2D and 3D culture formats. Sensor performance showed high consistency with conventional cell viability/cytotoxicity assays (MTT/CFDA-AM) for all toxicants, with the sensor IC 50 values matching the relevant viability LC 50 values at the 95% confidence interval range for 2D (DCF: 1.19-1.26 mM, MZB: 10.28-14.18 μM, OA: 40.91-77.13 nM) and 3D culture formats (DCF: 1.02-4.78 mM, MZB: 11.26-15.16 μM, OA: 162.09-179.67 nM). The presented results demonstrate the feasibility of the proposed sensor as a robust endpoint screening tool for both 2D and 3D cytotoxicity assessment.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom