z-logo
open-access-imgOpen Access
Effect of 18-Crown-6 on Oxytocin Stability in Aqueous Buffer Solutions
Author(s) -
Mostafa Ghasemisarabbadieh,
Sveinbjörn Gizurarson,
Benjamín R. Sveinbjörnsson
Publication year - 2021
Publication title -
acs omega
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.779
H-Index - 40
ISSN - 2470-1343
DOI - 10.1021/acsomega.0c06248
Subject(s) - chemistry , oxytocin , trifluoroacetic acid , chromatography , aqueous solution , 18 crown 6 , buffer (optical fiber) , ammonium acetate , phosphate , buffer solution , phase (matter) , crown (dentistry) , high performance liquid chromatography , biochemistry , organic chemistry , materials science , ion , medicine , telecommunications , computer science , composite material
In this study, the effect of 18-crown-6 on the stability of oxytocin in aqueous solution was explored. The study found that while 12-crown-4 and 15-crown-5 do not stabilize oxytocin, 18-crown-6 does have a stabilizing effect in citrate/phosphate buffer at pH 4.5. However, in acetate buffer at the same pH, the presence of 18-crown-6 had a destabilizing effect, possibly leading to a different degradation pathway. Both the stabilizing and destabilizing effects, depending on the buffer used, are concentration dependent where a higher concentration of 18-crown-6 is linked to a stronger effect. It is hypothesized that this effect may be linked to 18-crown-6 binding to the protonated ammonium group of oxytocin. Upon changing the mobile phase used in high-performance liquid chromatography experiments, we observed evidence supporting this binding hypothesis. When an acidic mobile phase was used (0.01% trifluoroacetic acid (TFA)), a partial shift in oxytocin retention time was observed for samples in acetate buffers in the presence of 18-crown-6 when using a 150 mm column (C18). The amount of the peak that shifted depended on the 18-crown-6 concentration used. A similar shift in oxytocin peak retention time was observed for samples in both acetate and citrate/phosphate buffers when using a 250 mm column (C18), but the peak completely shifted in those samples. When using an even more acidic mobile phase (0.1% TFA), the oxytocin peaks all had the same retention time again. Ultraviolet and nuclear magnetic resonance spectroscopy experiments also showed that the presence of 18-crown-6 has an observable effect on the resulting oxytocin spectra.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here