z-logo
open-access-imgOpen Access
Cleavage-Resistant Protein Labeling With Hydrophilic Trityl Enables Distance Measurements In-Cell
Author(s) -
Zikri Hasanbasri,
Kevin Singewald,
Teresa D. Gluth,
Benoît Driesschaert,
Sunil Saxena
Publication year - 2021
Publication title -
the journal of physical chemistry b
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.864
H-Index - 392
eISSN - 1520-6106
pISSN - 1520-5207
DOI - 10.1021/acs.jpcb.1c02371
Subject(s) - cleavage (geology) , maleimide , linker , xenopus , relaxation (psychology) , chemistry , electron paramagnetic resonance , analytical chemistry (journal) , biophysics , materials science , nuclear magnetic resonance , chromatography , polymer chemistry , biochemistry , physics , psychology , social psychology , fracture (geology) , biology , computer science , composite material , gene , operating system
Sensitive in-cell distance measurements in proteins using pulsed-electron spin resonance (ESR) require reduction-resistant and cleavage-resistant spin labels. Among the reduction-resistant moieties, the hydrophilic trityl core known as OX063 is promising due to its long phase-memory relaxation time ( T m ). This property leads to a sufficiently intense ESR signal for reliable distance measurements. Furthermore, the T m of OX063 remains sufficiently long at higher temperatures, opening the possibility for measurements at temperatures above 50 K. In this work, we synthesized deuterated OX063 with a maleimide linker (mOX063-d 24 ). We show that the combination of the hydrophilicity of the label and the maleimide linker enables high protein labeling that is cleavage-resistant in-cells . Distance measurements performed at 150 K using this label are more sensitive than the measurements at 80 K. The sensitivity gain is due to the significantly short longitudinal relaxation time ( T 1 ) at higher temperatures, which enables more data collection per unit of time. In addition to in vitro experiments, we perform distance measurements in Xenopus laevis oocytes. Interestingly, the T m of mOX063-d 24 is sufficiently long even in the crowded environment of the cell, leading to signals of appreciable intensity. Overall, mOX063-d 24 provides highly sensitive distance measurements both in vitro and in-cells .

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom