z-logo
open-access-imgOpen Access
Flame Retardant Chemicals in College Dormitories: Flammability Standards Influence Dust Concentrations
Author(s) -
Robin E. Dodson,
Kathryn M. Rodgers,
Gale B. Carey,
José Guillermo Cedeño Laurent,
Adrian Covaci,
Giulia Poma,
Govindan Malarvannan,
John D. Spengler,
Ruthann A. Rudel,
Joseph G. Allen
Publication year - 2017
Publication title -
environmental science and technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.851
H-Index - 397
eISSN - 1520-5851
pISSN - 0013-936X
DOI - 10.1021/acs.est.7b00429
Subject(s) - hexabromocyclododecane , flammability , fire retardant , environmental science , polybrominated diphenyl ethers , environmental chemistry , chemistry , organic chemistry , pollutant
Furniture flammability standards are typically met with chemical flame retardants (FRs). FRs can migrate out of products into dust and are linked to cancer, neurological impairment, and endocrine disruption. We collected 95 dust samples from dormitory common areas and student rooms on two U.S. college campuses adhering to two different furniture flammability standards: Technical Bulletin 117 (TB117) and Technical Bulletin 133 (TB133). Because TB133 requires furniture to withstand a much-more-demanding test flame than TB117, we hypothesized that spaces with TB133 furniture would have higher levels of FRs in dust. We found all 47 targeted FRs, including 12 polybrominated diphenyl ether (PBDE) congeners, 19 other brominated FRs, 11 phosphorus FRs (PFRs), 2 Dechlorane-Plus (DP) isomers, and 3 hexabromocyclododecane (HBCDD) isomers in the 95 dust samples. We measured the highest reported U.S. concentrations for a number of FRs, including BDE 209 (up to 990 000 ng/g), which may be used to meet the TB133 standard. We prioritized 16 FRs and analyzed levels in relation to flammability standard as well as presence and age of furniture and electronics. Adherence to TB133 was associated with higher concentrations of BDE 209, decabromodiphenylethane (DBDPE), DPs, and HBCDD compared to adherence to TB117 in univariate models (p < 0.05). Student dormitory rooms tended to have higher levels of some FRs compared to common rooms, likely a result of the density of furniture and electronics. As flammability standards are updated, it is critical to understand their impact on exposure and health risks.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here