z-logo
open-access-imgOpen Access
Resonance-Frequency Modulation for Rapid, Point-of-Care Ebola-Glycoprotein Diagnosis with a Graphene-Based Field-Effect Biotransistor
Author(s) -
Arnab Maity,
Xiaoyu Sui,
Bing Jin,
Hongting Pu,
Kai J. Bottum,
Xingkang Huang,
Jingbo Chang,
Guihua Zhou,
Ganhua Lu,
Junhong Chen
Publication year - 2018
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/acs.analchem.8b03226
Subject(s) - sensitivity (control systems) , resonance (particle physics) , chemistry , inflection point , graphene , optoelectronics , nanotechnology , physics , electronic engineering , materials science , atomic physics , engineering , geometry , mathematics
Recent outbreaks of Ebola-virus infections in several countries demand a rapid point-of-care (POC)-detection strategy. This paper reports on an innovative pathway founded on electronic-resonance-frequency modulation to detect Ebola glycoprotein (GP), on the basis of a carrier-injection-trapping-release-transfer mechanism and the standard antibody-antigen-interaction principle within a dielectric-gated reduced graphene oxide (rGO) field-effect transistor (GFET). The sensitivity of Ebola detection can be significantly enhanced by monitoring the device's electronic-resonance frequency, such as its inflection frequency ( f i ), where the phase angle reaches a maximum (θ max ). In addition to excellent selectivity, a sensitivity of ∼36-160% and ∼17-40% for 0.001-3.401 mg/L Ebola GP can be achieved at high and low inflection-resonance frequencies, respectively, which are several orders of magnitude higher than the sensitivity from other electronic parameters (e.g., resistance-based sensitivity). Using equivalent circuit modeling for contributions from channel and contact, analytical equations for resonance shifts have been generalized. When matching with the incoming ac-measurement signal, electronic resonance from the phase-angle spectrum evolves from various relaxation processes (e.g., trap and release of injected charges at surface-trap sites of the channel-gate oxide and channel-source or drain interfaces) that are associated with a characteristic emission frequency. Using charge-relaxation dynamics, a high-performance bio-FET sensing platform for healthcare and bioelectronic applications is realized through resonance shifting.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom