z-logo
open-access-imgOpen Access
Immunoassay for Detection of Infliximab in Whole Blood Using a Fiber-Optic Surface Plasmon Resonance Biosensor
Author(s) -
Jiadi Lu,
Dragana Spasić,
Filip Delport,
Thomas Van Stappen,
Iris Detrez,
Devin Daems,
Séverine Vermeire,
Ann Gils,
Jeroen Lammertyn
Publication year - 2017
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/acs.analchem.6b05092
Subject(s) - chemistry , surface plasmon resonance , biosensor , analyte , immunoassay , optical fiber , infliximab , chromatography , analytical chemistry (journal) , nanotechnology , optics , nanoparticle , biochemistry , tumor necrosis factor alpha , medicine , materials science , antibody , immunology , physics , biology
Monitoring the concentration of a therapeutic drug antibody, infliximab (IFX), is recommended for enhancing its efficacy in patients with inflammatory bowel disease (IBD). However, IFX concentrations are currently determined in patients' serum/plasma, which requires sample preparation from blood, hence hampering the turnaround time. In this paper, we present a short immunoassay (10 min) using a fiber-optic surface plasmon resonance (FO-SPR) biosensor for detection of IFX spiked in 100-fold diluted serum, plasma, and whole blood. The calculated limits of detection (LOD) based on calibration curves were 1.42, 1.00, and 1.34 ng/mL, respectively, which coincides with expected IFX concentrations in diluted samples from IBD patients. A linear correlation was established among different matrixes, indicating that the matrix effect was insignificant. The established point-of-care (POC) FO-SPR bioassay was also used to measure IFX in 100-fold diluted extracts of dried blood spots (DBS), and LOD achieved was below 2 ng/mL. Although DBS might be ideal for POC, this is the first report of using an SPR biosensor for measuring DBS samples. Finally, the POC FO-SPR immunoassay was validated by using matching serum and plasma samples from five IBD patients. A Pearson correlation of 0.968 was obtained between serum and plasma samples. IFX concentrations determined with FO-SPR were compared to a clinically validated enzyme-linked immunosorbent assay (ELISA), resulting in excellent Pearson correlation and intraclass correlation coefficient, both being 0.99 for serum and plasma samples. In conclusion, this paper demonstrates that our FO-SPR biosensor can be used as a true POC diagnostic tool for determining IFX concentrations in a variety of matrixes.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom