Salt Segregation and Sample Cleanup on Perfluoro-Coated Nanostructured Surfaces for Laser Desorption Ionization Mass Spectrometry of Biofluid Samples
Author(s) -
Ya Zhou,
Peng Chen,
Kenneth D. Harris,
Rupasri Mandal,
D. Jed Harrison
Publication year - 2017
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/acs.analchem.6b03934
Subject(s) - chemistry , mass spectrometry , desorption , salt (chemistry) , sample preparation , surface enhanced laser desorption/ionization , ionization , laser , desorption electrospray ionization , chromatography , analytical chemistry (journal) , sample preparation in mass spectrometry , electrospray ionization , chemical ionization , adsorption , ion , organic chemistry , optics , physics
We present a surface assisted laser desorption ionization (SALDI) technique, coupled with fluorocarbon coating, to achieve selective segregation of ionic and/or hydrophilic analytes from background biofluid electrolytes for quantiatve mass spectrometric analysis. By controlling the contact angle of (1H,1H,2H,2H-perfluorooctyl) trichlorosilane or (1H,1H,2H,2H-perfluorooctyl) dimethylchlorosilane to a specific range (105-120°), background electrolytes can be made to segregate from hydrophilic analytes during a drying step on the surface of a highly nanoporous thin film. Nanoporous silicon films were prepared using glancing angle deposition (GLAD) thin film technology, then coated with fluorcarbon. This desalting method directly separates highly polar, ionic metabolites, such as amino acids, from salty biofluids such as aritificial cerebrospinal fluid (aCSF) and serum. Derivatization, extraction and rinsing steps are not required to separate the analytes from the bioelectrolytes. With on-chip desalting, the limit of quantitation for histidine spiked in aCSF is ∼1 μM, and calibration curves with internal standards can achieve a precision of 1-9% within a 1 to 50 μM range. Five highly polar organic acids in serum were successfully quantified, and the SALDI-MS results obtained on the desalted serum sample spots show both good reproducibility and compare well to results from NMR and liquid chromatography-mass spectrometry. Putative identification of a total of 32 metabolites was accomplished in blood using time-of-flight MS with perfluoro coated Si-GLAD SALDI, by comparison to tabulated data.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom